Howard Industries manufactures a complete line of transformers, all designed with increased margins of safety and reliability. Contact your distributor or factory representative for availability of other kVA sizes, voltage ratings, features, accessories and design standards not listed.
Talk to us about filling a custom order that best fits your needs.
KVA Ratings (65° Rise): | 5, 10, 15, 25, 37.5, 50, 75, 100 |
High-Voltage Ratings: | 4160GrdY/2400 through 34500GrdY/19920 (60 kV through 200 kV BIL) |
Low-Voltage Ratings: | 120, 120/340, 240/480, 277, 346 or 600 (30 kV BIL) |
Meets or exceeds current IEEE, NEMA,RUS,ASTM, and DOE standards as applicable | |
Shell-type core/coil construction | |
Wet-process porcelain high-voltage bushings (oil-filled at 125 kV BIL and above for reduced radio interference) | |
Molded polymer or wet-process porcelain low-voltage bushings | |
Tin-plated bronze terminals suitable for connection to copper or aluminum | |
Low-voltage grounding provision | |
Low-voltage ground strap | |
Permanently stamped identification on internal secondary leads for ease of paralleling | |
Visible cover ground connected to upper mounting bracket | |
Tank grounding provisions | |
Tank ground connectors | |
Low-voltage circuit breaker with external operating handle (no light, no overload) | |
Internal high-voltage expulsion fuse | |
Lightning arrester, externally-mounted | |
Automatic pressure relief valve for added safety | |
Mineral oil with oxidation inhibitor | |
Mild steel tank, cover and ring | |
Continuous-bead welding on lifting lugs and mounting brackets for increased safety and corrosion resistance | |
Recessed tank bottom for scuff protection | |
Tough powder-paint finish for improved resistance to abrasion and corrosion | |
15 kV minimum cover and ring insulation | |
Corrosion-resistant cover-ring hardware | |
KVA marking on tank | |
Internal oil-level mark | |
Laser-engraved aluminum nameplate |
Stainless steel tank and/or cover and/or cover ring | |
High-voltage tap switch with external operating handle: | |
• 5-2.5% taps above normal | |
• 5-2.5% taps below normal | |
• 2-2.5% taps above and below normal | |
• Taps at 13800/13200/12870/12540 for units rated 14400 | |
Dual high-voltage switch with external operating handle | |
Interlaced low-voltage windings | |
Amorphous Metal Core | |
Drain valve with oil sampling device | |
Temperature gauge | |
Liquid level gauge | |
Pressure/vacuum gauge | |
Wildlife protection | |
Ester-based dielectric fluid | |
Custom stenciling and labeling | |
Laser engraved stainless steel nameplate | |
Other non-U.S. design standards | |
Low-voltage circuit breaker with external operating handle (with light, with overload) | |
Under oil current limiting fuse | |
Internal fault detector (IFD) |